Main Properties

  • Measurement of active energy in direct and reactive energy in direct and reverse directions, for one or multiple tariffs in three-phase three-wire and four-wire AC circuits, with transformer and/or direct connection for voltage and current
  • Accuracy class for active energy measurement according to DSTU EN 62053-21 – 1.0
  • Accuracy class for active energy measurement according to DSTU EN 50470-1 and DSTU EN 50470-3 – B
  • Accuracy class for active energy measurement according to DSTU EN 50470-1 and DSTU EN 50470-3 – C
  • Accuracy class for active energy measurement according to DSTU EN 62053-22 – 0.5s
  • Accuracy class for reactive energy measurement according to DSTU EN 62053-23 – 2.0
  • Nominal voltage – 3x220 / 380 V, 3x230 / 400 V, 3x240 / 416 V or 3x57.7 / 100V, multi-voltage (depending on the configuration)
  • Frequency – 50 Hz
  • Nominal current – 5 A
  • Maximum current – 10 A, 80 A or 120 A (depending on the configuration)
  • Protection degree – IP54
  • Presence of an optical port for programming and data reading
  • Number of LCD digits – 6+3
  • For multi-tariff configuration: up to 4 tariffs and 12 time zones with automatic transition to winter and summer time
  • Inter-verification interval – 10 years
  • Average service life (before the first major overhaul) – 24 years

Advantages

  • Registration and indication of active, reactive, and apparent power, power factor, RMS voltage and current, and phase angle displacement for each phase in three-phase three-wire and four-wire AC circuits
  • Extended operating voltage range (3x50 / 87 V – 3x270 / 467 V)
  • Enhanced protection against the effects of constant and variable magnetic fields (SOU-N MPE 40.1.35.110:2005)
  • Technological accuracy reserve of at least 50%
  • Low self-energy consumption
  • Non-detachable housing
  • Transparent casing
  • Option to install an LCD backlight module (optional)
  • Option to install a load control relay up to 120 A (optional)
  • In the absence of voltage at the meter terminals, it can operate in indication mode from a battery for reading values
  • Indication of magnetic field influence with an induction value above 100 mT
  • Indication of electromagnetic field influence with an intensity above 10 V/m in the frequency range of 80-2000 MHz
  • Additional service functions: indication of incorrect connections, reverse current direction, tamper sensors for the housing and terminal cover
  • Storage of events with date and time stamp in non-volatile memory
  • Capability to disconnect consumer load when exceeding set limits: power limit, current and voltage, constant magnetic field influence above 100 mT, and electromagnetic field above 10 V/m, disconnection for non-payment
  • Capability to install modules of 2 interfaces: "ZigBee" radio module, RS-485, PLC, GSM / GPRS, Ethernet for remote data reading, meter programming, and use in AMi systems

Table of Configurations