NIK 7051 ultrasonic meter
NIK 7051 ultrasonic meter
General properties:
- It is equipped with:
- NIK 7051 computer
- Flow-measuring area (NIK 7041 or flow-measuring area of the outsourced manufacturer)
- Resistance temperature detector Pt500/Pt1000
- Type – ultrasonic water/heating meter
- Number of LCD digits – 8
- Grade of accuracy – 2
- Connection type - true union
- Channels for connection of the computers: 3
- Amount of channels for temperature measurement: 3 (Pt500 / Pt1000)
- Connection pattern of temperature sensors: two- or four-wire
- Optical port, standard IEC EN 1434-1 – 2
- Threshold sensitivity - 1/5 of minimum flow
- Cable length standard – 2m
- Cable length max – 10m
- Calibration interval – 4 years
Advantages:
- Not sensitive towards external magnetic action
- In-built self-diagnostics system
- Daily, hourly and monthly archives and event archive
- Wireless data transfer to the higher-level system
- No moving parts, it shows no mechanical wear